私は Smart Array P420i を搭載した DL380p を持っています。このサーバーにはいくつかの論理ドライブがあります:
root@server:~# hpacucli ctrl all show config
Smart Array P420i in Slot 0 (Embedded) (sn: XXXXXXX)
array A (Solid State SATA, Unused Space: 0 MB)
logicaldrive 1 (119.2 GB, RAID 0, OK)
physicaldrive 1I:2:1 (port 1I:box 2:bay 1, Solid State SATA, 128.0 GB, OK)
array B (SATA, Unused Space: 0 MB)
logicaldrive 2 (1.8 TB, RAID 1+0, Failed)
physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SATA, 250.0 GB, Failed)
physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SATA, 250.0 GB, Failed)
physicaldrive 1I:2:4 (port 1I:box 2:bay 4, SATA, 2 TB, Failed)
physicaldrive 2I:2:5 (port 2I:box 2:bay 5, SATA, 2 TB, Failed)
array C (Solid State SATA, Unused Space: 0 MB)
logicaldrive 3 (931.5 GB, RAID 0, OK)
physicaldrive 2I:2:6 (port 2I:box 2:bay 6, Solid State SATA, 1 TB, OK)
array D (Solid State SATA, Unused Space: 0 MB)
logicaldrive 4 (931.5 GB, RAID 0, OK)
physicaldrive 2I:2:7 (port 2I:box 2:bay 7, Solid State SATA, 1 TB, OK)
array E (Solid State SATA, Unused Space: 0 MB)
logicaldrive 5 (931.5 GB, RAID 0, OK)
physicaldrive 2I:2:8 (port 2I:box 2:bay 8, Solid State SATA, 1 TB, OK)
SEP (Vendor ID XXXX, Model XXXXX) 380 (WWID: XXXXXXX)
アレイ B は論理ドライブから削除されましたが、このコマンドを実行すると:
root@server:~# hpacucli ctrl slot=0 ld 2 delete
Warning: Deleting an array can cause other array letters to become renamed.
E.g. Deleting array A from arrays A,B,C will result in two remaining
arrays A,B ... not B,C
Warning: Deleting the specified device(s) will result in data being lost.
Continue? (y/n) n
この論理ドライブを削除する前に、この ld を削除すると文字の名前が変更されるかどうかを知りたいのですが。同じ文字でこのアレイ B を再作成したいからです。したがって、この手順を実行するためにこのシステムを再起動しますが、ダウンタイムなしでこの手順を実行したいのです。誰か助けてくれませんか?
最高
答え1
アレイのラベル付けには連続した文字を使用します。アレイ B を削除すると、現在のアレイ C、D、E はそれぞれ B、C、D になります。これらのアレイ文字は、ACU がディスクのグループを参照する際に便宜上使用するものです。オペレーティング システムはアレイではなく論理ボリュームを認識するため、どこかのスクリプトにアレイ文字がハードコードされていない限り、アレイの文字を変更しても大きな影響はありません。