Das CD-Fach meines T400 springt manchmal von selbst heraus. Aber wenn ich es durch Drücken der Taste auswerfen möchte, reagiert es nicht. Wie kann ich das Problem beheben? Danke. Ubuntu 12.04
Hier sind einige Befehle.
$ eject -v
eject: using default device `cdrom'
eject: device name is `cdrom'
eject: expanded name is `/dev/cdrom'
eject: `/dev/cdrom' is a link to `/dev/sr0'
eject: `/dev/sr0' is not mounted
eject: `/dev/sr0' is not a mount point
eject: `/dev/sr0' is not a multipartition device
eject: trying to eject `/dev/sr0' using CD-ROM eject command
eject: CD-ROM eject command succeeded
$ sudo umount /dev/cdrom
umount: /dev/cdrom: not mounted
$ sudo eject /dev/cdrom -v
eject: device name is `/dev/cdrom'
eject: expanded name is `/dev/cdrom'
eject: `/dev/cdrom' is a link to `/dev/sr0'
eject: `/dev/sr0' is not mounted
eject: `/dev/sr0' is not a mount point
eject: `/dev/sr0' is not a multipartition device
eject: trying to eject `/dev/sr0' using CD-ROM eject command
eject: CD-ROM eject command succeeded
Informationen dazu
*-cdrom
description: DVD-RAM writer
product: DVDRAM GSA-U20N
vendor: HL-DT-ST
physical id: 1
bus info: scsi@1:0.0.0
logical name: /dev/cdrom
logical name: /dev/cdrw
logical name: /dev/dvd
logical name: /dev/dvdrw
logical name: /dev/sr0
version: HX12
capabilities: removable audio cd-r cd-rw dvd dvd-r dvd-ram
configuration: ansiversion=5 status=open
Antwort1
Mein Problem ist bei Ubuntu 14.04 ähnlich. Wenn ich mit "eject" eine Daten-CD entnehme und dann das leere Fach schließe, funktioniert der Knopf am Fach nicht mehr. Der Befehl "sudo eject -v" kann das Fach nicht öffnen. Ich glaube nicht, dass es sich um einen Hardwarefehler handelt, da der Knopf nach einem Neustart wieder funktioniert.