Seit einiger Zeit erhalte ich nach jedem Neustart meiner Workstation (der sogenannte „Charm“) E-Mails wie die folgenden.
Subject: SMART error (ErrorCount) detected on host: charm
This message was generated by the smartd daemon running on:
host name: charm
DNS domain: jj5.net
The following warning/error was logged by the smartd daemon:
Device: /dev/nvme3, number of Error Log entries increased from 324 to 326
Device info:
PNY CS3140 1TB SSD, S/N:PNY21242106180100094, FW:CS314312, 1.00 TB
For details see host's SYSLOG.
You can also use the smartctl utility for further investigation.
The original message about this issue was sent at Sat Feb 4 12:53:13 2023 AEDT
Another message will be sent in 24 hours if the problem persists.
Ich erhalte bei jedem Neustart vier dieser E-Mails, eine für jedes NVMe-SSD-Laufwerk, das ich in meiner Workstation habe. Wie Sie aus der Fehler-E-Mail ersehen können, sind meine LaufwerkePNY CS3140 1TB SSDs. Ich habe vier davon. Ich glaube nicht, dass dieses Problem nur bei meinen PNY-Laufwerken auftritt, denn ich habe das gleiche Problem, das ich hier beschreibe, auf einem anderen Computer, der Samsung 990 PRO NVMe-Laufwerke verwendet.
Als ich meinen Arbeitsplatz zum ersten Mal einrichtete, folgte ich dem Rat vonDieser Artikelund habe die Ashift-Einstellung meiner ZFS-Zpools auf 14 gesetzt. Im Artikel stand, dass ich den Wert auf 12 erhöhen sollte und dass ein höherer Wert nicht schaden würde. Ich dachte, dass mein SMART-Fehlerproblem mit dieser ZFS-Ashift-Einstellung zusammenhängen könnte, also habe ich mein Betriebssystem (Ubuntu) neu installiert und meine ZFS-Zpools ohne die Ashift-Einstellung wie folgt neu erstellt:
DISK1=/dev/disk/by-id/nvme-eui.6479a74fb0c00509
DISK2=/dev/disk/by-id/nvme-eui.6479a74fb0c00507
DISK3=/dev/disk/by-id/nvme-eui.6479a74fb0c004b7
DISK4=/dev/disk/by-id/nvme-eui.6479a74fb0c00508
zpool create -f \
-o autotrim=on \
-O acltype=posixacl -O compression=off \
-O dnodesize=auto -O normalization=formD -O atime=off -O dedup=off \
-O xattr=sa \
best ${DISK1}-part4 ${DISK2}-part4 ${DISK3}-part4 ${DISK4}-part4
zpool create -f \
-o autotrim=on \
-O acltype=posixacl -O compression=lz4 \
-O dnodesize=auto -O normalization=formD -O atime=off -O dedup=on \
-O xattr=sa \
fast mirror ${DISK1}-part5 ${DISK2}-part5 mirror ${DISK3}-part5 ${DISK4}-part5
Ich habe eine Ashift-Einstellung automatisch erkennen lassen und es hat für alle meine Festplatten die Einstellung 9 ausgewählt:
$ zdb | grep ashift
ashift: 9
ashift: 9
ashift: 9
ashift: 9
ashift: 9
ashift: 9
Das könnte Sie auch interessieren:
$ cat /proc/partitions | grep -v loop
major minor #blocks name
259 0 976762584 nvme1n1
259 2 1100800 nvme1n1p1
259 3 1048576 nvme1n1p2
259 4 52428800 nvme1n1p3
259 5 104857600 nvme1n1p4
259 6 817324032 nvme1n1p5
259 1 976762584 nvme0n1
259 7 1100800 nvme0n1p1
259 8 1048576 nvme0n1p2
259 9 52428800 nvme0n1p3
259 10 104857600 nvme0n1p4
259 11 817324032 nvme0n1p5
259 12 976762584 nvme2n1
259 14 1100800 nvme2n1p1
259 15 1048576 nvme2n1p2
259 16 52428800 nvme2n1p3
259 17 104857600 nvme2n1p4
259 18 817324032 nvme2n1p5
259 13 976762584 nvme3n1
259 19 1100800 nvme3n1p1
259 20 1048576 nvme3n1p2
259 21 52428800 nvme3n1p3
259 22 104857600 nvme3n1p4
259 23 817324032 nvme3n1p5
9 1 104790016 md1
259 24 104787968 md1p1
9 0 2093056 md0
259 25 2091008 md0p1
11 0 1048575 sr0
und das:
$ cat /proc/mdstat
Personalities : [raid10] [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4]
md0 : active raid10 nvme3n1p2[2] nvme1n1p2[2] nvme2n1p2[0] nvme0n1p2[3]
2093056 blocks super 1.2 512K chunks 2 near-copies [4/4] [UUUU]
md1 : active raid10 nvme2n1p3[3] nvme3n1p3[2] nvme1n1p3[0] nvme0n1p3[2]
104790016 blocks super 1.2 512K chunks 2 near-copies [4/4] [UUUU]
unused devices: <none>
Hier sind einige ausgewählte Ausgaben von df
:
$ df -h
Filesystem Size Used Avail Use% Mounted on
/dev/md1p1 100G 47G 51G 48% /
/dev/md0p1 2.0G 261M 1.6G 15% /boot
/dev/nvme2n1p1 1.1G 6.1M 1.1G 1% /boot/efi
best 325G 128K 325G 1% /best
fast 1006G 128K 1006G 1% /fast
Das Root-Dateisystem ist btrfs.
Wie Sie bei meinen SSDs sehen, verwende ich die Partitionen 2 und 3 für mdadm-RAID-Arrays und die Partitionen 4 und 5 für ZFS-Zpools „best“ und „fast“.
In der Fehlermeldung in den E-Mails heißt es, man solle das Syslog auf weitere Einzelheiten prüfen, aber das Syslog enthält nicht sehr viel:
$ cat /var/log/syslog | grep smartd
Feb 8 15:20:33 charm smartd[3202]: Device: /dev/nvme2, number of Error Log entries increased from 323 to 324
Feb 8 15:20:33 charm smartd[3202]: Sending warning via /usr/share/smartmontools/smartd-runner to root ...
Feb 8 15:20:33 charm smartd[3202]: Warning via /usr/share/smartmontools/smartd-runner to root: successful
Feb 10 13:47:49 charm smartd[3233]: smartd 7.2 2020-12-30 r5155 [x86_64-linux-5.15.0-60-generic] (local build)
Feb 10 13:47:49 charm smartd[3233]: Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
Feb 10 13:47:49 charm smartd[3233]: Opened configuration file /etc/smartd.conf
Feb 10 13:47:49 charm smartd[3233]: Drive: DEVICESCAN, implied '-a' Directive on line 21 of file /etc/smartd.conf
Feb 10 13:47:49 charm smartd[3233]: Configuration file /etc/smartd.conf was parsed, found DEVICESCAN, scanning devices
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme0, opened
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme0, PNY CS3140 1TB SSD, S/N:PNY21242106180100095, FW:CS314312, 1.00 TB
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme0, is SMART capable. Adding to "monitor" list.
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme0, state read from /var/lib/smartmontools/smartd.PNY_CS3140_1TB_SSD-PNY21242106180100095.nvme.state
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme1, opened
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme1, PNY CS3140 1TB SSD, S/N:PNY21242106180100093, FW:CS314312, 1.00 TB
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme1, is SMART capable. Adding to "monitor" list.
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme1, state read from /var/lib/smartmontools/smartd.PNY_CS3140_1TB_SSD-PNY21242106180100093.nvme.state
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme2, opened
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme2, PNY CS3140 1TB SSD, S/N:PNY21242106180100092, FW:CS314312, 1.00 TB
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme2, is SMART capable. Adding to "monitor" list.
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme2, state read from /var/lib/smartmontools/smartd.PNY_CS3140_1TB_SSD-PNY21242106180100092.nvme.state
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme3, opened
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme3, PNY CS3140 1TB SSD, S/N:PNY21242106180100094, FW:CS314312, 1.00 TB
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme3, is SMART capable. Adding to "monitor" list.
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme3, state read from /var/lib/smartmontools/smartd.PNY_CS3140_1TB_SSD-PNY21242106180100094.nvme.state
Feb 10 13:47:49 charm smartd[3233]: Monitoring 0 ATA/SATA, 0 SCSI/SAS and 4 NVMe devices
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme0, number of Error Log entries increased from 318 to 320
Feb 10 13:47:49 charm smartd[3233]: Sending warning via /usr/share/smartmontools/smartd-runner to root ...
Feb 10 13:47:49 charm smartd[3233]: Warning via /usr/share/smartmontools/smartd-runner to root: successful
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme1, number of Error Log entries increased from 321 to 323
Feb 10 13:47:49 charm smartd[3233]: Sending warning via /usr/share/smartmontools/smartd-runner to root ...
Feb 10 13:47:49 charm smartd[3233]: Warning via /usr/share/smartmontools/smartd-runner to root: successful
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme2, number of Error Log entries increased from 324 to 326
Feb 10 13:47:49 charm smartd[3233]: Sending warning via /usr/share/smartmontools/smartd-runner to root ...
Feb 10 13:47:49 charm smartd[3233]: Warning via /usr/share/smartmontools/smartd-runner to root: successful
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme3, number of Error Log entries increased from 324 to 326
Feb 10 13:47:49 charm smartd[3233]: Sending warning via /usr/share/smartmontools/smartd-runner to root ...
Feb 10 13:47:49 charm smartd[3233]: Warning via /usr/share/smartmontools/smartd-runner to root: successful
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme0, state written to /var/lib/smartmontools/smartd.PNY_CS3140_1TB_SSD-PNY21242106180100095.nvme.state
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme1, state written to /var/lib/smartmontools/smartd.PNY_CS3140_1TB_SSD-PNY21242106180100093.nvme.state
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme2, state written to /var/lib/smartmontools/smartd.PNY_CS3140_1TB_SSD-PNY21242106180100092.nvme.state
Feb 10 13:47:49 charm smartd[3233]: Device: /dev/nvme3, state written to /var/lib/smartmontools/smartd.PNY_CS3140_1TB_SSD-PNY21242106180100094.nvme.state
Hier ist eine Ausgabe smartctl -x
für das NVMe3-Gerät:
# smartctl -x /dev/nvme3
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.0-60-generic] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PNY CS3140 1TB SSD
Serial Number: PNY21242106180100094
Firmware Version: CS314312
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 1,000,204,886,016 [1.00 TB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 1,000,204,886,016 [1.00 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 4fb0c00508
Local Time is: Sat Feb 11 06:57:14 2023 AEDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 84 Celsius
Critical Comp. Temp. Threshold: 89 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 8.80W - - 0 0 0 0 0 0
1 + 7.10W - - 1 1 1 1 0 0
2 + 5.20W - - 2 2 2 2 0 0
3 - 0.0620W - - 3 3 3 3 2500 7500
4 - 0.0440W - - 4 4 4 4 10500 65000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 41 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 16%
Data Units Read: 21,133,741 [10.8 TB]
Data Units Written: 151,070,190 [77.3 TB]
Host Read Commands: 202,445,947
Host Write Commands: 2,302,434,105
Controller Busy Time: 5,268
Power Cycles: 58
Power On Hours: 7,801
Unsafe Shutdowns: 33
Media and Data Integrity Errors: 0
Error Information Log Entries: 326
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 326 0 0x1018 0x4004 0x028 0 0 -
Ich bin mir also nicht sicher, was der Fehler wirklich ist. Ich bin mir nicht sicher, was ihn verursacht. Ich bin mir nicht sicher, wie ernst es ist (alles scheint zu funktionieren). Und insbesondere bin ich mir nicht sicher, wie ich dieses Problem lösen kann.
Ich bin für jeden Vorschlag dankbar.
Antwort1
Ich habe das gleiche Problem, allerdings mit Crucial P3 CT4000P3SSD8. Ich habe zwei gleiche im ZFS-Mirrorpool unter Ubuntu 22.04 (Kernel 5.15.0-67-generic) laufen und jeder einzelne Systemneustart fügt dem SMART-Fehlerprotokoll für jedes Laufwerk 2 Fehler hinzu.
Ich habe nvme-cli installiert und ausgeführt nvme error-log /dev/<your_drive>
. Im Protokoll habe ich den Fehler gefunden:0x2002(INVALID_FIELD: A reserved coded value or an unsupported value in a defined field).
ich fanddieser Threadauf nvme-cli
der GitHub-Seite von , insbesonderedieser Kommentarvon @keithbusch mit den Worten:
Der SQID ist die Admin-Warteschlange,Der Fehler deutet also wahrscheinlich darauf hin, dass der Treiber oder ein anderes Tool einen harmlosen optionalen Befehl versucht hat, den Ihr Controller nicht unterstützt.. Der Gerätehersteller ist dafür bekannt, dass er diese Fehler sehr genau protokolliert. Die Spezifikation erlaubt dieses Verhalten, aber es ist weder erforderlich, noch ist es für irgendjemanden hilfreich.
Ich denke, wir sind sicher, wir müssen nur lernen, mit dieser übermäßigen Protokollierung zu leben …