Wie beurteilt man den Verschleißgrad einer NVMe-SSD?

Wie beurteilt man den Verschleißgrad einer NVMe-SSD?

Ich habe einen Laptop mit NVMe-SSD:

# nvme list

Node             SN                   Model                                    Namespace Usage                      Format           FW Rev  
---------------- -------------------- ---------------------------------------- --------- -------------------------- ---------------- --------
/dev/nvme0n1     <-CENSORED->         KXG50ZNV512G NVMe TOSHIBA 512GB          1         512.11  GB / 512.11  GB    512   B +  0 B   AADA4107

SMART sagt mir nicht,üblichRohwerte außer dem ~22 TB geschrieben.

# smartctl -a /dev/nvme0n1

smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.0-74-generic] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Number:                       KXG50ZNV512G NVMe TOSHIBA 512GB
Serial Number:                      <-CENSORED->
Firmware Version:                   AADA4107
PCI Vendor/Subsystem ID:            0x1179
IEEE OUI Identifier:                0x00080d
Total NVM Capacity:                 512,110,190,592 [512 GB]
Unallocated NVM Capacity:           0
Controller ID:                      0
Number of Namespaces:               1
Namespace 1 Size/Capacity:          512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size:     512
Namespace 1 IEEE EUI-64:            00080d 0500023e1d
Local Time is:                      Thu Jun  3 14:12:35 2021 CEST
Firmware Updates (0x14):            2 Slots, no Reset required
Optional Admin Commands (0x0017):   Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f):     Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Maximum Data Transfer Size:         512 Pages
Warning  Comp. Temp. Threshold:     78 Celsius
Critical Comp. Temp. Threshold:     82 Celsius
Namespace 1 Features (0x02):        NA_Fields

Supported Power States
St Op     Max   Active     Idle   RL RT WL WT  Ent_Lat  Ex_Lat
 0 +     6.00W       -        -    0  0  0  0        0       0
 1 +     2.40W       -        -    1  1  1  1        0       0
 2 +     1.90W       -        -    2  2  2  2        0       0
 3 -   0.0500W       -        -    3  3  3  3     1500    1500
 4 -   0.0030W       -        -    4  4  4  4    50000   80000

Supported LBA Sizes (NSID 0x1)
Id Fmt  Data  Metadt  Rel_Perf
 0 +     512       0         2
 1 -    4096       0         1

=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

SMART/Health Information (NVMe Log 0x02)
Critical Warning:                   0x00
Temperature:                        35 Celsius
Available Spare:                    100%
Available Spare Threshold:          10%
Percentage Used:                    9%
Data Units Read:                    63,196,994 [32.3 TB]
Data Units Written:                 43,370,182 [22.2 TB]
Host Read Commands:                 549,038,974
Host Write Commands:                420,271,939
Controller Busy Time:               2,885
Power Cycles:                       2,160
Power On Hours:                     17,684
Unsafe Shutdowns:                   211
Media and Data Integrity Errors:    0
Error Information Log Entries:      0
Warning  Comp. Temperature Time:    0
Critical Comp. Temperature Time:    0
Temperature Sensor 1:               35 Celsius

Error Information (NVMe Log 0x01, max 128 entries)
No Errors Logged

Außerdem habe ich mir gerade Folgendes angesehen:

# nvme error-log /dev/nvme0n1

und es enthält nur 64 dieser Einträge:

.................
error_count  : 0
sqid         : 0
cmdid        : 0
status_field : 0(SUCCESS: The command completed successfully)
parm_err_loc : 0
lba          : 0
nsid         : 0
vs           : 0
cs           : 0
.................

Frage: Kann ich den Abnutzungsgrad meiner SSD ermitteln? Vielleicht über dieVerfügbares ErsatzteilStichworte?

Antwort1

Der Abnutzungsgrad wird durch das Feld „Prozentsatz der Nutzung“ angegeben.was angegeben wird als(Seite 184):

Verwendeter Prozentsatz:Enthält eine herstellerspezifische Schätzung des Prozentsatzes der verbrauchten Lebensdauer des NVM-Subsystems basierend auf der tatsächlichen Nutzung und der Vorhersage der NVM-Lebensdauer durch den Hersteller. Ein Wert von 100 gibt an, dass die geschätzte Lebensdauer des NVM im NVM-Subsystem verbraucht ist, weist aber möglicherweise nicht auf einen Ausfall des NVM-Subsystems hin. Der Wert darf 100 überschreiten. Prozentsätze über 254 werden als 255 dargestellt. Dieser Wert wird einmal pro Einschaltstunde aktualisiert (wenn sich der Controller nicht im Ruhezustand befindet).

verwandte Informationen