ICH HABE EINEN HP PROLIANT SERVER DL 180 G6. DIESER SERVER WIRD PLÖTZLICH NEU GESTARTET, MANCHMAL ZWEI- ODER DREIMAL AM TAG, MANCHMAL NACH 2 TAGEN ODER NACH 7 TAGEN. (Screenshot vom Neustart)
Ich habe das HP Smart Storage Administrator Tool ausgeführt (siehe Screenshot).
ADU REPORT
ADU Version 2.30.6.0
Diagnostic Module Version 8.3.6.0
Time Generated Friday January 20, 2017 2:22:11PM
Device Summary:
Smart Array P410 in Embedded Slot
Consolidated Error Report:
Controller: Smart Array P410 in Embedded Slot
Message: An unknown cache error was detected.
Controller: Smart Array P410 in Embedded Slot
Message: The cache is permanently disabled.
Report for Smart Array P410 in Embedded Slot
--------------------------------------------
Smart Array P410 in Embedded Slot : Device Error Report
Device Severity Error
--------------------------------- -------- ------------------------------------
Smart Array P410 in Embedded Slot Warning An unknown cache error was detected.
Smart Array P410 in Embedded Slot Critical The cache is permanently disabled.
Antwort1
Es gibt keinen besseren Grund, als den HP-Support anzurufen und einen Techniker anzufordern. Das letzte Mal, soweit ich mich erinnere, hat der Techniker den Smart Array/RAID-Controller ausgetauscht. Grüße
Antwort2
Ihr RAID-Cache-Modul ist defekt, sodass der Controller den Write-Back-Cache vollständig deaktiviert hat. Es scheint sich nicht um ein einfaches Batterieproblem zu handeln; möglicherweise ist der DRAM-Cache-Speicher selbst defekt.
Sie können selbst nichts tun, außer einen anderen identischen Controller zu kaufen und den defekten zu ersetzen. Wenn Sie können, rufen Sie jedoch HP an und bitten Sie um Ersatz.