TENGO UN SERVIDOR HP PROLIANT DL 180 G6. ESTE SERVIDOR SE REINICIA REPENTINAMENTE, EN ALGUNAS VECES DOS O TRES VECES EN UN DÍA, EN ALGUNAS VECES DESPUÉS DE 2 DÍAS O DESPUÉS DE 7 DÍAS. (Reiniciar captura de pantalla)
He ejecutado la herramienta de administrador de almacenamiento inteligente hp (ver captura de pantalla).
ADU REPORT
ADU Version 2.30.6.0
Diagnostic Module Version 8.3.6.0
Time Generated Friday January 20, 2017 2:22:11PM
Device Summary:
Smart Array P410 in Embedded Slot
Consolidated Error Report:
Controller: Smart Array P410 in Embedded Slot
Message: An unknown cache error was detected.
Controller: Smart Array P410 in Embedded Slot
Message: The cache is permanently disabled.
Report for Smart Array P410 in Embedded Slot
--------------------------------------------
Smart Array P410 in Embedded Slot : Device Error Report
Device Severity Error
--------------------------------- -------- ------------------------------------
Smart Array P410 in Embedded Slot Warning An unknown cache error was detected.
Smart Array P410 in Embedded Slot Critical The cache is permanently disabled.
Respuesta1
No hay mejor razón para llamar al soporte técnico de HP para solicitar un técnico. La última vez que recuerdo, el técnico reemplazó el controlador Smart Array/raid. Saludos
Respuesta2
Su módulo de caché RAID está defectuoso, por lo que el controlador deshabilitó por completo el caché de reescritura. No parece ser un simple problema de batería; tal vez la memoria caché DRAM esté rota.
No hay nada que pueda hacer usted mismo, salvo comprar otro controlador idéntico y reemplazar el que falla. Sin embargo, si puede, abra una llamada de soporte con HP y solicite un reemplazo.