Error SMART (CurrentPendingSector) detectado en el host

Error SMART (CurrentPendingSector) detectado en el host

Smart informa el siguiente error todos los días en uno de los SSD del servidor de mi centro de datos:

This message was generated by the smartd daemon running on:

   host name:  x
   DNS domain: x

The following warning/error was logged by the smartd daemon:

Device: /dev/sda [SAT], 1 Currently unreadable (pending) sectors

Device info:
INTEL SSDSC2BB480G7, S/N:PHDV701605XT480BGN, WWN:5-5cd2e4-14d60bdf9, FW:N2010101, 480 GB

For details see host's SYSLOG.

You can also use the smartctl utility for further investigation.
The original message about this issue was sent at Tue Feb  6 18:43:41 2018 EST
Another message will be sent in 24 hours if the problem persists.

Syslog, no muestra información adicional.

Leí en otra parte que necesito realizar una prueba inteligente extendida, luego escribir en el sector especificado en los resultados de la prueba para forzar a la unidad a marcarlo como un sector defectuoso y reasignarlo.

Hice una prueba larga:

sudo smartctl -t long /dev/sda1

¿Pero el resultado de Sudo smartctl -a /dev/sda1 dice que la prueba se completó sin errores?

smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.4.98-2-pve] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     INTEL SSDSC2BB480G7
Serial Number:    PHDV701605XT480BGN
LU WWN Device Id: 5 5cd2e4 14d60bdf9
Firmware Version: N2010101
User Capacity:    480,103,981,056 bytes [480 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-3 T13/2161-D revision 5
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Wed Feb 21 04:58:20 2018 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x02) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (   72) seconds.
Offline data collection
capabilities:                    (0x79) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (   2) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0032   100   100   000    Old_age   Always       -       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       8753
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       11
170 Unknown_Attribute       0x0033   100   100   010    Pre-fail  Always       -       0
171 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
172 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
174 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       9
175 Program_Fail_Count_Chip 0x0033   100   100   010    Pre-fail  Always       -       270807480494
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       -       0
184 End-to-End_Error        0x0033   100   100   090    Pre-fail  Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   070   064   000    Old_age   Always       -       30 (Min/Max 16/37)
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       9
194 Temperature_Celsius     0x0022   100   100   000    Old_age   Always       -       30
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       1
199 UDMA_CRC_Error_Count    0x003e   100   100   000    Old_age   Always       -       0
225 Unknown_SSD_Attribute   0x0032   100   100   000    Old_age   Always       -       415161
226 Unknown_SSD_Attribute   0x0032   100   100   000    Old_age   Always       -       1126
227 Unknown_SSD_Attribute   0x0032   100   100   000    Old_age   Always       -       51
228 Power-off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       525179
232 Available_Reservd_Space 0x0033   100   100   010    Pre-fail  Always       -       0
233 Media_Wearout_Indicator 0x0032   099   099   000    Old_age   Always       -       0
234 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
241 Total_LBAs_Written      0x0032   100   100   000    Old_age   Always       -       415161
242 Total_LBAs_Read         0x0032   100   100   000    Old_age   Always       -       433149
243 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       979238

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%      8753         -
# 2  Extended offline    Completed without error       00%      8752         -
# 3  Extended offline    Completed without error       00%      8464         -
# 4  Short offline       Completed without error       00%       888         -
# 5  Short offline       Completed without error       00%       886         -
# 6  Short offline       Completed without error       00%       885         -
# 7  Short offline       Completed without error       00%         0         -
# 8  Short offline       Completed without error       00%         0         -
# 9  Short offline       Completed without error       00%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

¿Existe realmente un problema y, de ser así, cómo diagnosticarlo correctamente?

Respuesta1

Sólo 1 sector pendiente no es un problema para una unidad. Simplemente ignórelo hasta que aumente significativamente.

Aunque puedes intentar solucionarlo siguiendo las siguientes instrucciones (¡primero haz una copia de seguridad de los datos!):https://github.com/smartmontools/smartmontools/blob/master/www/BadBlockHowTo.txt

También puede comparar su informe Drive SMART con otros eneste repositorio de informes SMART.

Respuesta2

La gran pregunta es si ese sector tiene datos que le interesan, intente leer sus archivos de datos y vea si falta algo.

En cualquier caso, para evitar que se repita este mensaje de error, deberá sobrescribir los datos para permitir que la unidad lo ignore. También debería funcionar recortar el bloque si no tiene otro uso. Puedes intentar hacer un fstrim en el sistema de archivos para borrar esto.

La prueba larga SMART realiza una prueba aleatoria de los medios y no es una prueba completa, por lo que puede tener éxito incluso si hay un error y especialmente si se trata de un error de tipo recuperable, ya que el fabricante no querría que se produzca un solo error pendiente. hacer que usted RMA la unidad.

información relacionada