내 데비안 시스템이 갑자기 작동을 멈췄습니다. 재부팅했을 때 암호화 비밀번호를 입력하기 전에 오류가 표시되었습니다failed to IDENTIFY after ACPI commands
mdadm: device 1 in /dev/md/1 has wrong state superblock, but /dev/sdc3 seems ok
그리고 그 이후RAID status not OK. Exiting. ... failed!
또한 시스템을 부팅한 후에도 smartctl -i /dev/sdc
반환되었습니다.
User Capacity: 600 332 565 813 390 450 bytes [600 PB]
Logical block size: 774843950 bytes
scsiModePageOffset: response length too short, resp_len=47 offset=50 bd_len=46
>> Terminate command early due to bad response to IEC mode page
A mandatory SMART command failed: exiting. To continue, add one or more '-T permissive' options.
다시 재부팅하면 이 메시지가 표시되지만 mdadm: /dev/md0 has been started with 1 drive (out of 2)
이번에
mdadm: /dev/md1 has been started with 1 drive (out of 2)
는 출력이 smartctl -i /dev/sdc
괜찮은 것 같습니다.
User Capacity: 128 035 676 160 bytes [128 GB]
Sector Size: 512 bytes logical/physical
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
내용/proc/mdstat
Personalities : [raid1]
md1 : active raid1 sda3[0]
124716928 blocks super 1.2 [2/1] [U_]
md0 : active raid1 sda2[0]
249664 blocks super 1.2 [2/1] [U_]
unused devices: <none>
SSD가 작동하는지 확인하고 RAID가 제대로 작동하는지 확인하는 방법은 무엇입니까?
업데이트: /sbin/badblocks -v -s /dev/sdc
0개의 오류를 반환했으므로 HW 문제는 없는 것 같습니다.
답변1
핀이 타거나 손상되지 않도록 SSD를 올바른 방향으로 연결했는지 확인하십시오. 이 시스템을 방금 설정했다면 거기서부터 시작하겠습니다.