LSI RAID가 동기화되지 않음

LSI RAID가 동기화되지 않음

RAID가 포함된 HS22 블레이드가 있습니다. 미러링된 디스크 중 하나를 제거하고 다른 디스크에 사용했는데 지금 다시 삽입하고 있는데 작업 디스크에서 동기화가 되지 않습니다.

cfggen다음을 보여줍니다:

cfggen_linux_i686_x86-64/cfggen 0 display
LSI Logic IR Configuration Utility 2.06.00
Read configuration has been initiated for controller 0
------------------------------------------------------------------------
Controller information
------------------------------------------------------------------------
  Controller type                         : SAS1064E
  BIOS version                            : 6.30.00.00
  Firmware version                        : 1.30.05.00
  Channel description                     : 1 Serial Attached SCSI
  Initiator ID                            : 112
  Maximum physical devices                : 62
  Concurrent commands supported           : 277
  Slot                                    : 0
  Bus                                     : 11
  Device                                  : 0
  Function                                : 0
  RAID Support                            : Yes
------------------------------------------------------------------------
IR Volume information
------------------------------------------------------------------------
IR volume 1
  Volume ID                               : 1
  Status of volume                        : Degraded (DGD)
  RAID level                              : 1
  Size (in MB)                            : 285148
  Physical hard disks (Target ID)         : 3 255
IR volume 2
  Volume ID                               : 132
  Status of volume                        : Inactive, Okay (OKY)
  RAID level                              : 1
  Size (in MB)                            : 285148
------------------------------------------------------------------------
Physical device information
------------------------------------------------------------------------
Initiator at ID #112
Target on ID #2
  Device is a Hard disk
  Enclosure #                             : 1
  Slot #                                  : 1
  Connector ID                            : 1
  Target ID                               : 2
  State                                   : Online (ONL)
  Size (in MB)/(in sectors)               : 286102/585937500
  Manufacturer                            : IBM-ESXS
  Model Number                            : CBRCA300C3ETS0
  Firmware Revision                       : C370
  Serial No                               :
  Drive Type                              : SAS
  Protocol                                : SAS
Target on ID #3
  Device is a Hard disk
  Enclosure #                             : 1
  Slot #                                  : 0
  Connector ID                            : 0
  Target ID                               : 3
  State                                   : Online (ONL)
  Size (in MB)/(in sectors)               : 286102/585937500
  Manufacturer                            : IBM-ESXS
  Model Number                            : CBRCA300C3ETS0
  Firmware Revision                       : C370
  Serial No                               :         PDVTTZME
  Drive Type                              : SAS
  Protocol                                : SAS
------------------------------------------------------------------------
Enclosure information
------------------------------------------------------------------------
Enclosure#                                : 1
  Logical ID                              : 088306cc:5005076b
  Numslots                                : 4
  StartSlot                               : 0
  Start TargetID                          : 0
  Start Bus                               : 0

무엇을 해야 할까요?

답변1

내가 그것을 얻었을 경우 RAID1에서 1개의 디스크를 분리한 다음 다른 서버에서 스위치를 켜고 결국 원래 서버에 다시 도입했습니다. 그렇다면 컨트롤러는 다른 디스크에서 미러링해야 하는 기본 디스크가 무엇인지 혼동될 수 있습니다. .

데이터를 수신해야 하는 디스크를 다시 초기화할 수 있나요? 이렇게 하면 해당 디스크에서 RAID 정보가 지워집니다.

관련 정보