Smart는 매일 내 데이터 센터 서버 SSD 중 하나에서 다음 오류를 보고합니다.
This message was generated by the smartd daemon running on:
host name: x
DNS domain: x
The following warning/error was logged by the smartd daemon:
Device: /dev/sda [SAT], 1 Currently unreadable (pending) sectors
Device info:
INTEL SSDSC2BB480G7, S/N:PHDV701605XT480BGN, WWN:5-5cd2e4-14d60bdf9, FW:N2010101, 480 GB
For details see host's SYSLOG.
You can also use the smartctl utility for further investigation.
The original message about this issue was sent at Tue Feb 6 18:43:41 2018 EST
Another message will be sent in 24 hours if the problem persists.
Syslog에는 추가 정보가 표시되지 않습니다.
확장된 스마트 테스트를 수행한 다음 테스트 결과에 지정된 섹터에 기록하여 드라이브가 이를 불량 섹터로 표시하고 재할당하도록 해야 한다는 내용을 다른 곳에서 읽었습니다.
나는 긴 테스트를 실행했습니다.
sudo smartctl -t long /dev/sda1
그러나 sudo smartctl -a /dev/sda1의 출력에는 테스트가 오류 없이 완료되었다고 나와 있습니까?
smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.4.98-2-pve] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: INTEL SSDSC2BB480G7
Serial Number: PHDV701605XT480BGN
LU WWN Device Id: 5 5cd2e4 14d60bdf9
Firmware Version: N2010101
User Capacity: 480,103,981,056 bytes [480 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Feb 21 04:58:20 2018 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 72) seconds.
Offline data collection
capabilities: (0x79) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 2) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
5 Reallocated_Sector_Ct 0x0032 100 100 000 Old_age Always - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 8753
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 11
170 Unknown_Attribute 0x0033 100 100 010 Pre-fail Always - 0
171 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
172 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
174 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 9
175 Program_Fail_Count_Chip 0x0033 100 100 010 Pre-fail Always - 270807480494
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
184 End-to-End_Error 0x0033 100 100 090 Pre-fail Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x0022 070 064 000 Old_age Always - 30 (Min/Max 16/37)
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 9
194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 30
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 1
199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
225 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 415161
226 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 1126
227 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 51
228 Power-off_Retract_Count 0x0032 100 100 000 Old_age Always - 525179
232 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0
233 Media_Wearout_Indicator 0x0032 099 099 000 Old_age Always - 0
234 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 415161
242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 433149
243 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 979238
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 8753 -
# 2 Extended offline Completed without error 00% 8752 -
# 3 Extended offline Completed without error 00% 8464 -
# 4 Short offline Completed without error 00% 888 -
# 5 Short offline Completed without error 00% 886 -
# 6 Short offline Completed without error 00% 885 -
# 7 Short offline Completed without error 00% 0 -
# 8 Short offline Completed without error 00% 0 -
# 9 Short offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
정말 문제가 있는 걸까요? 그렇다면 제대로 진단하는 방법은 무엇인가요?
답변1
단 1개의 보류 섹터만 드라이브에 문제가 되지 않습니다. 눈에 띄게 증가할 때까지 무시하세요.
다음 지침을 사용하여 문제를 해결할 수 있지만(먼저 데이터를 백업하세요!):https://github.com/smartmontools/smartmontools/blob/master/www/BadBlockHowTo.txt
또한 드라이브 SMART 보고서를 다른 보고서와 비교할 수 있습니다.이 SMART 보고서 저장소.
답변2
가장 큰 질문은 해당 섹터에 관심 있는 데이터가 있는지 여부입니다. 데이터 파일을 읽고 누락된 것이 있는지 확인하십시오.
어떤 경우에도 이 오류 메시지가 반복되는 것을 방지하려면 드라이브가 이를 무시할 수 있도록 데이터를 덮어써야 합니다. 다른 용도로 사용되지 않는 블록을 자르는 것도 효과가 있습니다. 이 문제를 해결하려면 파일 시스템에서 fstrim을 수행해 보세요.
SMART 장기 테스트는 미디어에 대해 무작위 테스트를 수행하며 완전한 테스트가 아니므로 오류가 있어도 성공할 수 있으며 특히 제조업체가 보류 중인 단일 오류가 발생하는 것을 원하지 않기 때문에 복구 가능한 오류인 경우 더욱 그렇습니다. 드라이브를 RMA하게 됩니다.