100% iowait + falhas de unidade no dmesg

100% iowait + falhas de unidade no dmesg

Eu tenho um servidor no qual reside um aplicativo da web bastante visitado.
Possui um raid1 de 2 HDDs, buffer de 64 MB, 7200 RPM.
Hoje começou a lançar erros como:

kernel: ata2.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen
kernel: ata2.00: cmd b0/d0:01:00:4f:c2/00:00:00:00:00/00 tag 0 pio 512 in
kernel: res 40/00:00:00:4f:c2/00:00:00:00:00/00 Emask 0x4 (timeout)
kernel: ata2.00: status: { DRDY }
kernel: ata2: hard resetting link
kernel: ata2: SATA link up 3.0 Gbps (SStatus 123 SControl 300)
kernel: ata2.00: max_sectors limited to 256 for NCQ
kernel: ata2.00: max_sectors limited to 256 for NCQ
kernel: ata2.00: configured for UDMA/133
kernel: sd 1:0:0:0: timing out command, waited 7s
kernel: ata2: EH complete
kernel: SCSI device sda: 976773168 512-byte hdwr sectors (500108 MB)
kernel: sda: Write Protect is off
kernel: SCSI device sda: drive cache: write back    

Durante todo o dia esteve com carga superior a 10-15.
Estou monitorando-o com o top e dá algumas leituras bizarras:

DSK |          sda | busy    100% | read       2 | write    208 | KiB/r     16 | KiB/w     32 | MBr/s   0.00 | MBw/s   0.65 | avq    86.17 | avio 47.6 ms |
DSK |          sdb | busy      1% | read      10 | write    117 | KiB/r     17 | KiB/w      5 | MBr/s   0.02 | MBw/s   0.07 | avq     4.86 | avio 1.04 ms |

Francamente, não entendo por que apenas o sda está sofrendo todo o impacto. Eu tenho um processo que está constantemente escrevendo com 1-2 megas, mas que diabos... 100% iowait?

Atualização:
smartctl -A /dev/sda

ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate     0x002f   200   200   051    Pre-fail  Always       -       0
3 Spin_Up_Time            0x0027   239   239   021    Pre-fail  Always       -       8050
4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       22
5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       -       0
7 Seek_Error_Rate         0x002e   200   200   000    Old_age   Always       -       0
9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       595
10 Spin_Retry_Count        0x0032   100   253   000    Old_age   Always       -       0
11 Calibration_Retry_Count 0x0032   100   253   000    Old_age   Always       -       0
12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -        21
192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       -       20
193 Load_Cycle_Count        0x0032   200   200   000    Old_age   Always       -       22
194 Temperature_Celsius     0x0022   118   106   000    Old_age   Always       -       32
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       -       0 
197 Current_Pending_Sector  0x0032   200   200   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0030   100   253   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x0008   100   253   000    Old_age   Offline      -       0

Responder1

Parece que a unidade pode estar falhando - o sistema está redefinindo a unidade/conexão tentando acessá-la. Suponho que, como você pode ver o status de sda ​​e sdb, é uma invasão de software, portanto, você deve poder verificar /proc/mdstat para ver o que pode estar acontecendo com a invasão de software.

O IOWait ocorre porque o ataque de software está sendo retido aguardando para gravar no sda. Isso, por sua vez, está atrasando os processos e causando o alto número de carga.

Você deve substituir seu sda o mais rápido possível.

Responder2

Parece um disco com defeito para mim ...

Responder3

sda não está processando solicitações de E/S prontamente. Se não for a unidade, há um desequilíbrio na E/S. Você tem uma partição swap no sda? Nesse caso, você pode ter problemas de memória, resultando na destruição de páginas de memória dentro e fora da troca. Certifique-se de ter espaço de troca alocado em ambas as unidades com a mesma prioridade. O programa sar pode ser útil.

informação relacionada