Recebi um e-mail para root (mesmo erro no syslog)
O seguinte aviso/erro foi registrado pelo daemon smartd:
Device: /dev/bus/0 [megaraid_disk_12] [SAT], ATA error count increased from 0 to 9
Informação do dispositivo:
ST13000NM0005-2A1201, S/N:ZVJ2GZSP, WWN:5-000c50-0b3bg13c3, FW:SN02, 12.0 TB
Depois de executar dois testes nele,
$ smartctl -l selftest /dev/bus/0 -d megaraid,12
/dev/bus/0 [megaraid_disk_12] [SAT]: Device open changed type from 'megaraid,12' to 'sat+megaraid,12'
=== START OF READ SMART DATA SECTION ===
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 11445 -
# 2 Short offline Completed without error 00% 11427 -
NO storecli,
$ sudo storcli /call show
Generating detailed summary of the adapter, it may take a while to complete.
Controller = 0
Status = Success
Description = None
Virtual Drives = 3
VD LIST :
=======
------------------------------------------------------------
DG/VD TYPE State Access Consist Cache sCC Size Name
------------------------------------------------------------
0/0 RAID1 Optl RW Yes RWBD - 223.062 GB
1/1 RAID1 Optl RW Yes RWTD - 3.492 TB
2/2 RAID10 Optl RW Yes RWBD - 32.740 TB
------------------------------------------------------------
Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|B=Blocked|Consist=Consistent|
R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
Physical Drives = 12
PD LIST :
=======
-----------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
-----------------------------------------------------------------------------------
0:0 1 Onln 0 223.062 GB SATA SSD N N 512B INTEL SSDSC2******* U
0:1 2 Onln 0 223.062 GB SATA SSD N N 512B INTEL SSDSC2******* U
0:2 6 Onln 1 3.492 TB SATA SSD N N 512B Samsung SSD 883 DCT 3.84TB U
0:3 10 Onln 1 3.492 TB SATA SSD N N 512B Samsung SSD 883 DCT 3.84TB U
0:4 8 Onln 2 10.913 TB SATA HDD N N 512B ST13000NM0005-2A1201 U
0:5 11 Onln 2 10.913 TB SATA HDD N N 512B ST13000NM0005-2A1201 U
0:6 3 Onln 2 10.913 TB SATA HDD N N 512B ST13000NM0005-2A1201 U
0:7 4 Onln 2 10.913 TB SATA HDD N N 512B ST13000NM0005-2A1201 U
0:8 7 Onln 2 10.913 TB SATA HDD N N 512B ST13000NM0005-2A1201 U
0:9 12 Onln 2 10.913 TB SATA HDD N N 512B ST13000NM0005-2A1201 U
0:10 9 GHS - 10.913 TB SATA HDD N N 512B ST13000NM0005-2A1201 D
0:11 5 GHS - 10.913 TB SATA HDD N N 512B ST13000NM0005-2A1201 D
-----------------------------------------------------------------------------------
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: ATA return descriptor not supported by controller firmware
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 575) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: (1125) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x70bd) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 082 064 044 Pre-fail Always - 157163520
3 Spin_Up_Time 0x0003 090 090 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 11
5 Reallocated_Sector_Ct 0x0033 098 098 010 Pre-fail Always - 9208
7 Seek_Error_Rate 0x000f 090 060 045 Pre-fail Always - 920073154
9 Power_On_Hours 0x0032 087 087 000 Old_age Always - 11564
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 11
187 Reported_Uncorrect 0x0032 091 091 000 Old_age Always - 9
188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x0022 071 048 040 Old_age Always - 29 (Min/Max 24/52)
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 25
193 Load_Cycle_Count 0x0032 093 093 000 Old_age Always - 15951
194 Temperature_Celsius 0x0022 029 052 000 Old_age Always - 29 (0 22 0 0 0)
195 Hardware_ECC_Recovered 0x001a 082 064 000 Old_age Always - 157163520
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x0023 100 100 001 Pre-fail Always - 0
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 2824 (96 42 0)
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 3015256
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 3036621419213
SMART Error Log Version: 1
ATA Error Count: 9 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 9 occurred at disk power-on lifetime: 11377 hours (474 days + 1 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
42 00 00 ff ff ff 4f 00 39d+08:08:45.869 READ VERIFY SECTOR(S) EXT
42 00 01 ff ff ff 4f 00 39d+08:08:45.176 READ VERIFY SECTOR(S) EXT
35 00 01 ff ff ff 4f 00 39d+08:08:45.175 WRITE DMA EXT
42 00 00 ff ff ff 4f 00 39d+08:08:29.406 READ VERIFY SECTOR(S) EXT
42 00 00 ff ff ff 4f 00 39d+08:08:29.190 READ VERIFY SECTOR(S) EXT
Error 8 occurred at disk power-on lifetime: 11377 hours (474 days + 1 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
42 00 00 ff ff ff 4f 00 39d+08:08:29.406 READ VERIFY SECTOR(S) EXT
42 00 00 ff ff ff 4f 00 39d+08:08:29.190 READ VERIFY SECTOR(S) EXT
42 00 00 ff ff ff 4f 00 39d+08:08:29.119 READ VERIFY SECTOR(S) EXT
42 00 00 ff ff ff 4f 00 39d+08:08:28.814 READ VERIFY SECTOR(S) EXT
42 00 01 ff ff ff 4f 00 39d+08:08:28.143 READ VERIFY SECTOR(S) EXT
Error 7 occurred at disk power-on lifetime: 11377 hours (474 days + 1 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
42 00 00 ff ff ff 4f 00 39d+08:08:18.534 READ VERIFY SECTOR(S) EXT
42 00 00 ff ff ff 4f 00 39d+08:08:10.326 READ VERIFY SECTOR(S) EXT
42 00 01 ff ff ff 4f 00 39d+08:08:09.645 READ VERIFY SECTOR(S) EXT
35 00 01 ff ff ff 4f 00 39d+08:08:09.645 WRITE DMA EXT
42 00 00 ff ff ff 4f 00 39d+08:08:00.404 READ VERIFY SECTOR(S) EXT
Error 6 occurred at disk power-on lifetime: 11377 hours (474 days + 1 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
42 00 00 ff ff ff 4f 00 39d+08:08:00.404 READ VERIFY SECTOR(S) EXT
42 00 00 ff ff ff 4f 00 39d+08:08:00.226 READ VERIFY SECTOR(S) EXT
42 00 00 ff ff ff 4f 00 39d+08:08:00.083 READ VERIFY SECTOR(S) EXT
42 00 00 ff ff ff 4f 00 39d+08:07:57.845 READ VERIFY SECTOR(S) EXT
42 00 01 ff ff ff 4f 00 39d+08:07:57.215 READ VERIFY SECTOR(S) EXT
Error 5 occurred at disk power-on lifetime: 11377 hours (474 days + 1 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
42 00 00 ff ff ff 4f 00 39d+08:07:37.571 READ VERIFY SECTOR(S) EXT
42 00 00 ff ff ff 4f 00 39d+08:07:37.554 READ VERIFY SECTOR(S) EXT
42 00 00 ff ff ff 4f 00 39d+08:07:37.536 READ VERIFY SECTOR(S) EXT
42 00 00 ff ff ff 4f 00 39d+08:07:37.519 READ VERIFY SECTOR(S) EXT
42 00 00 ff ff ff 4f 00 39d+08:07:32.546 READ VERIFY SECTOR(S) EXT
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 11445 -
# 2 Short offline Completed without error 00% 11427 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Você pode ajudar a entender e obter o disco com falha, se houver. Obrigado
Responder1
Sim, este disco de 10 Tb, com número de série. ZVJ2GZSP
, está morrendo. Eu me pergunto por que o relatório inicial dizia que era 16 TB.
Já utilizou mais de 9.000 setores em área reservada:
5 Reallocated_Sector_Ct 0x0033 098 098 010 Pre-fail Always - 9208
Acho que você pode removê-lo com segurança, porque todo o armazenamento neste controlador RAID é redundante (RAID1 ou RAID 10) e tudo está ideal. Você deve definir este disco como offline. Depois que o disco estiver off-line, um dos GHS (hotspares globais) deverá ser ativado e substituir esse disco em sua matriz.
Este disco está no compartimento do gabinete no. 9 (lembre-se, estes são baseados em 0, então é o 10º). No entanto, para ter certeza, você pode usar a função de localização do seu gabinete.
Para obter detalhes, consulte o manual do controlador.