Eu tinha dois HDD de 1T e um RAID1 LVM LV de 500GB entre eles. Então adicionei outro HDD 2T e converti o LV para RAID5 usando
pvcreate /dev/sdd
vgextend ubuntu-vg /dev/sdd
lvconvert --type raid5 --stripes 2 ubuntu-vg/ubuntu-lv
Mas agora, quando listo todos os LVs, existem dois SubLVs, com o mesmo nome, no mesmo PV:
# lvs -a -o name,segtype,devices,size,path
LV Type Devices LSize Path
btest linear /dev/sdb(128002) 10.00g /dev/ubuntu-vg/btest
ctest linear /dev/sdc(128002) 10.00g /dev/ubuntu-vg/ctest
dtest linear /dev/sdd(128002) 10.00g /dev/ubuntu-vg/dtest
ubuntu-lv raid5 ubuntu-lv_rimage_0(0),ubuntu-lv_rimage_1(0),ubuntu-lv_rimage_2(0) 1000.00g /dev/ubuntu-vg/ubuntu-lv
[ubuntu-lv_rimage_0] linear /dev/sdb(128001) 500.00g
[ubuntu-lv_rimage_0] linear /dev/sdb(1) 500.00g
[ubuntu-lv_rimage_1] linear /dev/sdc(128001) 500.00g
[ubuntu-lv_rimage_1] linear /dev/sdc(1) 500.00g
[ubuntu-lv_rimage_2] linear /dev/sdd(128001) 500.00g
[ubuntu-lv_rimage_2] linear /dev/sdd(1) 500.00g
[ubuntu-lv_rmeta_0] linear /dev/sdb(0) 4.00m
[ubuntu-lv_rmeta_1] linear /dev/sdc(0) 4.00m
[ubuntu-lv_rmeta_2] linear /dev/sdd(0) 4.00m
( [b-d]test
foi criado após a conversão para testar a velocidade de leitura/gravação em HDDs individuais)
Por exemplo /dev/sdb(1)
, e /dev/sdb(128001)
são nomeados ubuntu-lv_rimage_0
e têm 500G de tamanho, mas pvs
mostram apenas 500G alocados em /dev/sdb
:
# pvs
PV VG Fmt Attr PSize PFree
/dev/sdb ubuntu-vg lvm2 a-- 931.51g <421.51g
/dev/sdc ubuntu-vg lvm2 a-- 931.51g <421.51g
/dev/sdd ubuntu-vg lvm2 a-- <1.82t 1.32t
Isso é normal? Se não, como posso corrigi-lo?
EDITAR:Acho que são dois segmentos de um LV, só o formato de saída é lvs
um pouco confuso. O segundo segmento é criado para converter RAID1 em RAID5. Como posso excluí-lo?
# lvs -a -o name,seg_pe_ranges ubuntu-vg/ubuntu-lv_rimage_0
LV PE Ranges
[ubuntu-lv_rimage_0] /dev/sdb:128001-128001
[ubuntu-lv_rimage_0] /dev/sdb:1-127999