Escrevi um script buscando a configuração RAID do VirtualDisk mais recente.
Em um servidor eu recebo:
# omreport storage vdisk controller=0 -fmt ssv | awk '-F;' '/^ID/{print}/Virtual\s*Disk\s*[0-9]+;/{line=$0;value=$7}END{print line;print value}'
ID;Status;Name;State;Hot Spare Policy violated;Encrypted;Layout;Size;T10 Protection Information Status;Associated Fluid Cache State ;Device Name;Bus Protocol;Media;Read Policy;Write Policy;Cache Policy;Stripe Element Size;Disk Cache Policy
14;Ok;VirtualDisk16;Ready;Not Applicable;No;RAID-0;7,451.50 GB (8000987201536 bytes);No;Not Applicable;/dev/sdo;SAS;HDD;No Read Ahead;Write Through;Not Applicable;64 KB;Unchanged
RAID-0
#
Em outro servidor, recebo:
# omreport storage vdisk controller=0 -fmt ssv | awk '-F;' '/^ID/{print}/Virtual\s*Disk\s*[0-9]+;/{line=$0;value=$7}END{print line;print value}'
ID;Status;Name;State;Hot Spare Policy violated;Virtual Disk Bad Blocks;Encrypted;Layout;Size;T10 Protection Information Status;Associated Fluid Cache State ;Device Name;Bus Protocol;Media;Read Policy;Write Policy;Cache Policy;Stripe Element Size;Disk Cache Policy
16;Ok;Virtual Disk 16;Ready;Not Applicable;No;No;RAID-0;3,725.50 GB (4000225165312 bytes);No;Not Applicable;/dev/sdp;SAS;HDD;Read Ahead;Force Write Back;Not Applicable;64 KB;Disabled
No
#
A diferença entre esses dois servidores é a versão do firmware PERC H730 Mini:
Segundo omreport system version
, o primeiro tem PERC H730 Mini v25.5.2.0001
e o segundo PERC H730 Mini v25.5.0.0018
.
Responder1
Provavelmente depende de omreport
versões diferentes ou de firmware. Em geral, tenha cuidado ao adaptar seu script para resultados muito específicos, pois qualquer pequena alteração pode prejudicar sua análise.