Por que omreport storage vdisk controller = 0 saída inconsistente entre servidores

Por que omreport storage vdisk controller = 0 saída inconsistente entre servidores

Escrevi um script buscando a configuração RAID do VirtualDisk mais recente.

Em um servidor eu recebo:

# omreport storage vdisk controller=0 -fmt ssv | awk '-F;' '/^ID/{print}/Virtual\s*Disk\s*[0-9]+;/{line=$0;value=$7}END{print line;print value}'
ID;Status;Name;State;Hot Spare Policy violated;Encrypted;Layout;Size;T10 Protection Information Status;Associated Fluid Cache State ;Device Name;Bus Protocol;Media;Read Policy;Write Policy;Cache Policy;Stripe Element Size;Disk Cache Policy
14;Ok;VirtualDisk16;Ready;Not Applicable;No;RAID-0;7,451.50 GB (8000987201536 bytes);No;Not Applicable;/dev/sdo;SAS;HDD;No Read Ahead;Write Through;Not Applicable;64 KB;Unchanged
RAID-0
#

Em outro servidor, recebo:

# omreport storage vdisk controller=0 -fmt ssv | awk '-F;' '/^ID/{print}/Virtual\s*Disk\s*[0-9]+;/{line=$0;value=$7}END{print line;print value}'
ID;Status;Name;State;Hot Spare Policy violated;Virtual Disk Bad Blocks;Encrypted;Layout;Size;T10 Protection Information Status;Associated Fluid Cache State ;Device Name;Bus Protocol;Media;Read Policy;Write Policy;Cache Policy;Stripe Element Size;Disk Cache Policy
16;Ok;Virtual Disk 16;Ready;Not Applicable;No;No;RAID-0;3,725.50 GB (4000225165312 bytes);No;Not Applicable;/dev/sdp;SAS;HDD;Read Ahead;Force Write Back;Not Applicable;64 KB;Disabled
No
#

A diferença entre esses dois servidores é a versão do firmware PERC H730 Mini:

Segundo omreport system version, o primeiro tem PERC H730 Mini v25.5.2.0001e o segundo PERC H730 Mini v25.5.0.0018.

Responder1

Provavelmente depende de omreportversões diferentes ou de firmware. Em geral, tenha cuidado ao adaptar seu script para resultados muito específicos, pois qualquer pequena alteração pode prejudicar sua análise.

informação relacionada