Não sei se isso é um problema de memória do servidor, de um dos meus SSDs ou de algo relacionado ao software. o acidente aconteceu mais de 4 vezes nos últimos meses.
Preciso de ajuda para descobrir como impedir que isso aconteça o mais rápido possível. Alguma ideia?
Aqui está o rastreamento de pilha:
SYSTEM_THREAD_EXCEPTION_NOT_HANDLED (7e)
This is a very common BugCheck. Usually the exception address pinpoints
the driver/function that caused the problem. Always note this address
as well as the link date of the driver/image that contains this address.
Arguments:
Arg1: ffffffffc0000005, The exception code that was not handled
Arg2: fffff8029ea8ba7b, The address that the exception occurred at
Arg3: ffff928ac148b858, Exception Record Address
Arg4: ffff928ac148b070, Context Record Address
KEY_VALUES_STRING: 1
Key : AV.Fault
Value: Read
Key : Analysis.CPU.mSec
Value: 3936
Key : Analysis.DebugAnalysisManager
Value: Create
Key : Analysis.Elapsed.mSec
Value: 3841
Key : Analysis.Init.CPU.mSec
Value: 17968
Key : Analysis.Init.Elapsed.mSec
Value: 585841
Key : Analysis.Memory.CommitPeak.Mb
Value: 130
Key : WER.OS.Branch
Value: fe_release_svc_prod2
Key : WER.OS.Timestamp
Value: 2022-07-07T18:32:00Z
Key : WER.OS.Version
Value: 10.0.20348.859
FILE_IN_CAB: MEMORY.DMP
DUMP_FILE_ATTRIBUTES: 0x1000
BUGCHECK_CODE: 7e
BUGCHECK_P1: ffffffffc0000005
BUGCHECK_P2: fffff8029ea8ba7b
BUGCHECK_P3: ffff928ac148b858
BUGCHECK_P4: ffff928ac148b070
EXCEPTION_RECORD: ffff928ac148b858 -- (.exr 0xffff928ac148b858)
ExceptionAddress: fffff8029ea8ba7b (HTTP!UlpGetSendCacheDataSize+0x0000000000000017)
ExceptionCode: c0000005 (Access violation)
ExceptionFlags: 00000000
NumberParameters: 2
Parameter[0]: 0000000000000000
Parameter[1]: ffffffffffffffff
Attempt to read from address ffffffffffffffff
CONTEXT: ffff928ac148b070 -- (.cxr 0xffff928ac148b070)
rax=0000000000000000 rbx=ffff80009068ed98 rcx=3a22707061222020
rdx=0000000000000000 rsi=ffffc38e63d74840 rdi=ffffc38e6414b030
rip=fffff8029ea8ba7b rsp=ffff928ac148ba98 rbp=ffff928ac148bb20
r8=0000000000000001 r9=00000000ffffffff r10=fffff80276af8d60
r11=ffff928ac148ba70 r12=0000000000000000 r13=ffffc38e6414b010
r14=ffffc38e63d748b0 r15=ffffc38e623aba80
iopl=0 nv up ei pl nz na pe nc
cs=0010 ss=0018 ds=002b es=002b fs=0053 gs=002b efl=00010202
HTTP!UlpGetSendCacheDataSize+0x17:
fffff802`9ea8ba7b 8b4128 mov eax,dword ptr [rcx+28h] ds:002b:3a227070`61222048=????????
Resetting default scope
BLACKBOXBSD: 1 (!blackboxbsd)
BLACKBOXNTFS: 1 (!blackboxntfs)
BLACKBOXPNP: 1 (!blackboxpnp)
BLACKBOXWINLOGON: 1
PROCESS_NAME: System
READ_ADDRESS: ffffffffffffffff
ERROR_CODE: (NTSTATUS) 0xc0000005 - The instruction at 0x%p referenced memory at 0x%p. The memory could not be %s.
EXCEPTION_CODE_STR: c0000005
EXCEPTION_PARAMETER1: 0000000000000000
EXCEPTION_PARAMETER2: ffffffffffffffff
EXCEPTION_STR: 0xc0000005
STACK_TEXT:
ffff928a`c148ba98 fffff802`9eb57402 : 00000000`00000001 ffffc38e`66bc0710 ffffc38e`646e6780 fffff802`76a3162f : HTTP!UlpGetSendCacheDataSize+0x17
ffff928a`c148baa0 fffff802`9eb2e012 : fffff802`9eb57301 fffff802`9eb33901 00000000`00000001 fffff802`9eb57380 : HTTP!UlSendCacheEntryWorker+0x82
ffff928a`c148bb60 fffff802`76b69f15 : ffffc38e`63d748b0 fffff802`9eafe580 00000000`00000480 00000000`00000000 : HTTP!UlpThreadPoolWorker+0x112
ffff928a`c148bbf0 fffff802`76c24488 : ffffad81`4ca40180 ffffc38e`646e6080 fffff802`76b69ec0 00000000`00000000 : nt!PspSystemThreadStartup+0x55
ffff928a`c148bc40 00000000`00000000 : ffff928a`c148c000 ffff928a`c1486000 00000000`00000000 00000000`00000000 : nt!KiStartSystemThread+0x28
SYMBOL_NAME: HTTP!UlpGetSendCacheDataSize+17
MODULE_NAME: HTTP
IMAGE_NAME: HTTP.sys
STACK_COMMAND: .cxr 0xffff928ac148b070 ; kb
BUCKET_ID_FUNC_OFFSET: 17
FAILURE_BUCKET_ID: AV_HTTP!UlpGetSendCacheDataSize
OS_VERSION: 10.0.20348.859
BUILDLAB_STR: fe_release_svc_prod2
OSPLATFORM_TYPE: x64
OSNAME: Windows 10
FAILURE_ID_HASH: {640925e0-41aa-2deb-fe92-17674389e426}
Followup: MachineOwner
---------
Responder1
É quase certo que isso está relacionado a uma atualização, você não é de longe o único a tê-lahttps://learn.microsoft.com/en-us/answers/questions/1185893/windows-server-2022-standard-(21h2-20348-1547)-cra
SE eu tivesse que adivinhar (não executo um ENV comparável para testar)https://learn.microsoft.com/en-us/security-updates/securitybulletins/2015/ms15-034provavelmente é por onde começar
OU
Seu sistema NÃO contém este patch e a natureza do CVEhttps://nvd.nist.gov/vuln/detail/CVE-2015-1635isso pode indicar que alguém está TENTANDO ativamente explorar o sistema. O fato de que outros começaram a receber o erroanteso patch de abril tende a favorecer essa teoria. Assim como uma violação de acesso em uma operação de memória!
SE a atualização estiver presente, eu reverteria e veria se isso ajuda (eu consideraria outra atenuação, se possível, e lembre-se de que este é um RCE).
Se ESTIVER presente, faça a captura de pacotes do sistema afetado, se possível, e correlacione o tráfego real para o servidor web com a instância da falha. Não seria o primeiro patch a não obter totalmente um bug que leva a outra variante ou levar à instabilidade por causa de um patch incompleto. Leve os resultados para a MS e deixe-os examinar para ter certeza de que o patch está correto.