У МЕНЯ ЕСТЬ ОДИН СЕРВЕР HP PROLIANT DL 180 G6. ЭТОТ СЕРВЕР ВНЕЗАПНО ПЕРЕЗАГРУЖАЕТСЯ, ТО ДВА ИЛИ ТРИ РАЗА В ДЕНЬ, ТО ЧЕРЕЗ 2 ДНЯ, ТО ЧЕРЕЗ 7 ДНЕЙ. (Скриншот перезагрузки)
Я запустил средство администратора HP Smart Storage (см. скриншот).
ADU REPORT
ADU Version 2.30.6.0
Diagnostic Module Version 8.3.6.0
Time Generated Friday January 20, 2017 2:22:11PM
Device Summary:
Smart Array P410 in Embedded Slot
Consolidated Error Report:
Controller: Smart Array P410 in Embedded Slot
Message: An unknown cache error was detected.
Controller: Smart Array P410 in Embedded Slot
Message: The cache is permanently disabled.
Report for Smart Array P410 in Embedded Slot
--------------------------------------------
Smart Array P410 in Embedded Slot : Device Error Report
Device Severity Error
--------------------------------- -------- ------------------------------------
Smart Array P410 in Embedded Slot Warning An unknown cache error was detected.
Smart Array P410 in Embedded Slot Critical The cache is permanently disabled.
решение1
Нет ничего лучше, чем позвонить в службу поддержки HP и запросить специалиста. В последний раз, насколько я помню, технический специалист заменил контроллер Smart Array/raid. С уважением
решение2
Ваш модуль кэша RAID неисправен, поэтому контроллер полностью отключил кэш обратной записи. Это не похоже на простую проблему с батареей; возможно, сломана сама кэш-память DRAM.
Вы ничего не можете сделать сами, разве что купить другой идентичный контроллер и заменить неисправный. Однако, если можете, откройте звонок в службу поддержки HP и попросите замену.