Я написал скрипт, извлекающий конфигурацию RAID последней версии VirtualDisk.
На одном сервере я получаю:
# omreport storage vdisk controller=0 -fmt ssv | awk '-F;' '/^ID/{print}/Virtual\s*Disk\s*[0-9]+;/{line=$0;value=$7}END{print line;print value}'
ID;Status;Name;State;Hot Spare Policy violated;Encrypted;Layout;Size;T10 Protection Information Status;Associated Fluid Cache State ;Device Name;Bus Protocol;Media;Read Policy;Write Policy;Cache Policy;Stripe Element Size;Disk Cache Policy
14;Ok;VirtualDisk16;Ready;Not Applicable;No;RAID-0;7,451.50 GB (8000987201536 bytes);No;Not Applicable;/dev/sdo;SAS;HDD;No Read Ahead;Write Through;Not Applicable;64 KB;Unchanged
RAID-0
#
На другом сервере я получаю:
# omreport storage vdisk controller=0 -fmt ssv | awk '-F;' '/^ID/{print}/Virtual\s*Disk\s*[0-9]+;/{line=$0;value=$7}END{print line;print value}'
ID;Status;Name;State;Hot Spare Policy violated;Virtual Disk Bad Blocks;Encrypted;Layout;Size;T10 Protection Information Status;Associated Fluid Cache State ;Device Name;Bus Protocol;Media;Read Policy;Write Policy;Cache Policy;Stripe Element Size;Disk Cache Policy
16;Ok;Virtual Disk 16;Ready;Not Applicable;No;No;RAID-0;3,725.50 GB (4000225165312 bytes);No;Not Applicable;/dev/sdp;SAS;HDD;Read Ahead;Force Write Back;Not Applicable;64 KB;Disabled
No
#
Разница между этими двумя серверами заключается в версии прошивки PERC H730 Mini:
Согласно omreport system version
, первый имеет PERC H730 Mini v25.5.2.0001
и второй PERC H730 Mini v25.5.0.0018
.
решение1
Вероятно, это зависит от разных omreport
версий прошивки. В общем, будьте осторожны, подгоняя свой скрипт под очень специфичный вывод, так как любое небольшое изменение может сломать ваш парсинг.