我有一台 HP PROLIANT 伺服器 DL 180 G6。該伺服器突然重新啟動,有時一天兩次或三次,有時在 2 天後或 7 天後。 (重啟截圖)
我已經運行了 hp 智慧型儲存管理員工具(看截圖)。
ADU REPORT
ADU Version 2.30.6.0
Diagnostic Module Version 8.3.6.0
Time Generated Friday January 20, 2017 2:22:11PM
Device Summary:
Smart Array P410 in Embedded Slot
Consolidated Error Report:
Controller: Smart Array P410 in Embedded Slot
Message: An unknown cache error was detected.
Controller: Smart Array P410 in Embedded Slot
Message: The cache is permanently disabled.
Report for Smart Array P410 in Embedded Slot
--------------------------------------------
Smart Array P410 in Embedded Slot : Device Error Report
Device Severity Error
--------------------------------- -------- ------------------------------------
Smart Array P410 in Embedded Slot Warning An unknown cache error was detected.
Smart Array P410 in Embedded Slot Critical The cache is permanently disabled.
答案1
沒有比這更好的理由打電話給 HP 支援來請求技術了 上次我記得技術人員更換了智慧陣列/raid 控制器 問候
答案2
您的 RAID 快取模組有缺陷,因此控制器完全停用了回寫式快取。這似乎不是一個簡單的電池問題;也許 DRAM 高速緩衝記憶體本身已損壞。
除了購買另一個相同的控制器並更換故障的控制器之外,您自己無能為力。但是,如果可以的話,請致電 HP 支援並要求更換。