橋接設備和網路介面卡是否應該共用相同的 IP 位址?

橋接設備和網路介面卡是否應該共用相同的 IP 位址?

如果我建立一個橋接設備,然後將其設定為我的 NIC 的主設備,那麼兩個設備似乎都具有相同的 IP 和兩個 MAC 位址。它是否正確?

2: eth0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq master br0 state UP group default qlen 1000
    link/ether xx:xx:xx:xx:xx:25 brd ff:ff:ff:ff:ff:ff
    inet 10.0.0.16/24 brd 10.0.0.255 scope global dynamic noprefixroute eth0
       valid_lft 2592sec preferred_lft 2142sec

3: br0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000
    link/ether xx:xx:xx:xx:xx:c1 brd ff:ff:ff:ff:ff:ff
    inet 10.0.0.16/24 brd 10.0.0.255 scope global dynamic br0
       valid_lft 3370sec preferred_lft 3370sec
    inet6 fe80::dea6:32ff:feaf:a125/64 scope link
       valid_lft forever preferred_lft forever

4: veth1@if8: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue master br0 state UP group default qlen 1000
    link/ether xx:xx:xx:xx:xx:c3 brd ff:ff:ff:ff:ff:ff link-netns ns1
    inet 169.254.31.45/16 brd 169.254.255.255 scope global noprefixroute veth1
       valid_lft forever preferred_lft forever

答案1

這不是正確的配置。橋接連接埠(在您的情況eth0veth1)不應有任何 IP 位址。