在外部儲存中寫入時,rsyslog 似乎會觸發 sdhci 轉儲

在外部儲存中寫入時,rsyslog 似乎會觸發 sdhci 轉儲

根據我的閱讀,rsyslog 通常用於處理日誌並將其發送到其他位置,可以是本地(外部儲存、特定分區等)或遠端(例如日誌伺服器)。不過,我正在嘗試配置 rsyslog 將日誌儲存在外部儲存裝置(SD 卡)中,但sdhci核心中的驅動程式出現問題。首先你這裡有rsyslog配置

正如您所看到的,日誌儲存在 中/data/logs,這實際上是 SD 卡,如下所示lsblk 輸出顯示。儘管如此,我還是看到了一件奇怪的事情訊息。顯然,核心正在/dev/mmcblk0為外部儲存建立節點,如下所示mmc0

jul 26 11:03:40 pabx2 kernel: mmc0: new ultra high speed SDR104 SDXC card at address 59b4
jul 26 11:03:40 pabx2 kernel: mmcblk0: mmc0:59b4 SD    58.9 GiB 
jul 26 11:03:40 pabx2 kernel:  mmcblk0: p1

sdhci垃圾場正在考慮mmc1!這是內部存儲,不是外部存儲!

jul 26 11:50:18 pabx2 kernel: mmc1: Timeout waiting for hardware interrupt.
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: Sys addr:  0x00000008 | Version:  0x00001002
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: Blk size:  0x00007200 | Blk cnt:  0x00000008
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: Argument:  0x0056c808 | Trn mode: 0x0000002b
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: Present:   0x1fff0001 | Host ctl: 0x0000003c
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: Power:     0x0000000a | Blk gap:  0x00000080
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: Wake-up:   0x00000000 | Clock:    0x00000207
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: Timeout:   0x00000006 | Int stat: 0x00000000
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: Int enab:  0x03ff000b | Sig enab: 0x03ff000b
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: ACmd stat: 0x00000000 | Slot int: 0x00000000
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: Caps:      0x546ec881 | Caps_1:   0x00000805
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: Cmd:       0x0000193a | Max curr: 0x00000000
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: Resp[0]:   0x00000000 | Resp[1]:  0x00000000
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: Resp[2]:   0x00000000 | Resp[3]:  0x00000000
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: Host ctl2: 0x0000000c
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: ADMA Err:  0x00000000 | ADMA Ptr: 0x0000000182ff6200
jul 26 11:50:18 pabx2 kernel: mmc1: sdhci: ============================================

你認為這是為什麼?內部儲存設備的硬體中斷與外部儲存有什麼關係?當這些轉儲被觸發時,系統(Debian 10 Buster)變得非常慢,甚至無法運作、無法使用。

謝謝你們。

相關內容