我有一個 encfs 加密的資料夾,只需剪切它的子資料夾的內容並將其貼到 encfs 加密的資料夾之外的另一個資料夾中。在執行此操作時,我收到一條錯誤訊息,指出無法刪除子資料夾,因為它不為空。
問題是,每個文件曾是貼到新資料夾中,舊資料夾中沒有留下任何文件,我ls -ll -a
在子資料夾中檢查了該文件:
total 8
drwxrwx--- 1 root plugdev 4096 Nov 9 16:19 .
drwxrwx--- 1 root plugdev 4096 Nov 9 16:19 ..
我不知道total 8
這裡應該給我哪些資訊。如果我嘗試,sudo ls -ll -a
它會說我沒有這樣做的權限。
基本上同樣適用於rm
.如果我這樣做rm -rf foldername
,它會說該資料夾不為空。如果我這樣做sudo rm -rf foldername
,它會說我沒有這樣做的權限。
更新(11 月 19 日):
的輸出sudo smartctl --all /dev/sda
是
smartctl 6.4 2014-10-07 r4002 [x86_64-linux-4.2.0-040200-generic] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: LITEONIT LMT-256M6M mSATA 256GB
Serial Number: TW0XXM30550853571923
Firmware Version: DM8110C
User Capacity: 256.060.514.304 bytes [256 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 4a
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Nov 19 10:20:30 2015 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 10) seconds.
Offline data collection
capabilities: (0x15) SMART execute Offline immediate.
No Auto Offline data collection support.
Abort Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0002) Does not save SMART data before
entering power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x00) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 10) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
5 Reallocated_Sector_Ct 0x0003 100 100 000 Pre-fail Always - 0
12 Power_Cycle_Count 0x0003 100 100 000 Pre-fail Always - 3655
175 Program_Fail_Count_Chip 0x0003 100 100 000 Pre-fail Always - 0
176 Erase_Fail_Count_Chip 0x0003 100 100 000 Pre-fail Always - 0
177 Wear_Leveling_Count 0x0003 100 100 000 Pre-fail Always - 222113
178 Used_Rsvd_Blk_Cnt_Chip 0x0003 100 100 000 Pre-fail Always - 0
179 Used_Rsvd_Blk_Cnt_Tot 0x0003 100 100 000 Pre-fail Always - 0
180 Unused_Rsvd_Blk_Cnt_Tot 0x0003 100 100 005 Pre-fail Always - 1664
181 Program_Fail_Cnt_Total 0x0003 100 100 000 Pre-fail Always - 0
182 Erase_Fail_Count_Total 0x0003 100 100 000 Pre-fail Always - 0
187 Reported_Uncorrect 0x0003 100 100 000 Pre-fail Always - 0
195 Hardware_ECC_Recovered 0x0003 100 100 000 Pre-fail Always - 0
241 Total_LBAs_Written 0x0003 100 100 000 Pre-fail Always - 286617
242 Total_LBAs_Read 0x0003 100 100 000 Pre-fail Always - 414678
SMART Error Log Version: 0
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 44292 -
# 2 Short offline Completed without error 00% 56577 -
# 3 Short offline Completed without error 00% 56321 -
# 4 Short offline Completed without error 00% 56321 -
# 5 Short offline Completed without error 00% 1024 -
# 6 Short offline Completed without error 00% 1024 -
# 7 Short offline Completed without error 00% 256 -
# 8 Extended offline Completed without error 00% 0 -
Selective Self-tests/Logging not supported
答案1
該資料夾可能是您加密磁碟區的安裝點。輸入mount
終端,然後查看加密磁碟機(儘管為空)是否仍安裝到該資料夾中。您可以使用sudo umount /path/to/folder
卸載它(可以說是“關閉加密系統”)。一旦該資料夾不再是活動安裝點,您應該能夠刪除該資料夾。